+86-159-2181-9772 | ben.liu@ulilaser.com

laser soldering process

Nov 27, 2026 · Industry News

The laser soldering process uses a focused laser beam as a localized heat source to reflow solder ball, solder paste or solder wire at a single joint, with the joint temperature held on a controlled profile by closed-loo…

The laser soldering process uses a focused laser beam as a localized heat source to reflow solder ball, solder paste or solder wire at a single joint, with the joint temperature held on a controlled profile by closed-loop pyrometer feedback rather than by an oven’s thermal mass. A typical cycle heats only the pad, lead and solder — not the whole assembly — reaching 245–260 °C at the joint in 0.3–3 seconds, which is why the process suits heat-sensitive packages, fine-pitch connectors and selective rework where a full reflow pass is either too slow or too risky. Getting repeatable results depends less on peak power than on energy density, ramp rate, focus height, flux activity and shielding gas, and on verifying each of those with measurable acceptance checks.

laser soldering process

How Does the Laser Soldering Process Work, Step by Step?

A production cell runs the same six steps for every joint, and each step has a measurable output:

  • 1. Part location and seating. CCD vision finds fiducials or pad edges and corrects X/Y/θ before heating. Look for repeatability of ±25 µm or better; any larger drift shows up later as one-sided fillets.
  • 2. Solder delivery. A ball is placed, paste is dispensed, or wire is fed to the joint. Deposited volume tolerance of ±10% is a practical target; volume variation is the single most common cause of joint-to-joint differences.
  • 3. Flux activation and preheat. The beam ramps the joint to 100–150 °C and holds briefly so flux can clean the surface and volatile carriers can escape before the solder melts.
  • 4. Reflow. The joint rises above liquidus (217 °C for SAC305) to a peak 25–40 °C above it, held just long enough for full collapse and fillet formation — usually 0.2–1.0 s above liquidus.
  • 5. Controlled cooling. Power ramps down over 0.1–0.5 s. Cooling rate affects grain structure; too-fast cooling on large pads can leave surface cracks, too-slow cooling grows intermetallic beyond the desired 1–4 µm.
  • 6. Inspection. Inline AOI checks position, fillet shape, wetting angle and solder presence; X-ray verifies voiding on thermal pads.

Note that this is soldering, not welding: the base metal never melts, and the joint is formed by a filler alloy wetting the pad and lead. Equipment, optics and process windows for fusion welding of base metal are a different discipline and do not transfer.

Which Process Parameters Define a Stable Laser Soldering Window?

The table below gives starting ranges for electronics assembly work. Treat them as a first trial window, then narrow it with a design-of-experiments run on your actual pad geometry.

Parameter Typical starting range Why it matters How to verify
Wavelength 915 nm or 976 nm diode; ~1070 nm fiber Shorter wavelengths absorb better in solder and copper; fiber sources suit larger spots Match to solder alloy and pad size in a trial
Spot diameter 0.3–3.0 mm, or shaped square/line Sets energy density and whether neighbouring parts are heated Burn-paper or beam profiler measurement at focus
Laser power at workpiece 5–150 W, joint dependent Must be high enough for the ramp, low enough to avoid overshoot Power meter at the nozzle, not at the source
Ramp rate 50–200 °C/s Fast ramps risk spatter; slow ramps oxidize and spread heat Recorded temperature curve per joint
Peak joint temperature Liquidus + 25–40 °C Drives wetting and fillet formation Calibrated pyrometer, cross-checked with thermocouple on a coupon
Time above liquidus 0.2–1.0 s Too short: incomplete collapse; too long: IMC growth, grain coarsening Profile analysis on the recorded curve
Focus height offset ±0.2 mm of nominal Defocus changes spot size and energy density Height sensor or gauge check at start of shift
Nitrogen shielding 99.99% N₂, O₂ below 1000 ppm, 15–30 L/min Reduces oxidation, improves wetting, widens the window In-line O₂ analyzer at the nozzle

Closed-loop temperature control is what makes these numbers hold. A pyrometer samples the joint at 1–10 kHz, and a PID loop modulates laser output within milliseconds. Two practical rules: the pyrometer’s measurement spot must be smaller than the heated area, and emissivity must be calibrated per pad finish — an uncalibrated emissivity of 0.3 versus 0.5 can read 30 °C off and quietly push every joint out of spec.

Solder Ball, Paste or Wire: Which Feeding Method Fits Your Product?

Method Typical size Best fit Watch-outs
Solder ball 0.15–1.0 mm diameter Through-hole, BGA/CSP reball, connector pins, consistent volume per joint Ball placement accuracy; ball must be pre-fluxed or flux-dipped
Solder paste Type 4–6 (25–15 µm powder) SMD pads, fine-pitch, mixed boards where volume is set by stencil or dispenser Flux outgassing causes voids; open time and slump limit the shift length
Solder wire 0.2–0.8 mm Wire-to-pad, terminal and shield attach, repair and low-volume builds Feed timing must match the ramp; wire must not pre-melt outside the beam

Where volume consistency is critical, ball feeding is easier to control because each joint receives a known mass. Where pad geometry varies across the board, paste gives more freedom. Wire remains the practical choice for terminals and repair stations. In all three cases the flux system — not the alloy — usually limits the process window, because outgassing during a fast ramp is what produces voids and spatter.

How Do You Troubleshoot Common Laser Soldering Defects?

Symptom Likely cause First corrective step
Dull, grainy, cold-looking joint Energy density too low; focus drifted; oxidized pad Check focus height, measure power at nozzle, verify N₂ flow and O₂ level
Solder ball not fully collapsed Time above liquidus too short; flux inactive; pad contamination Extend dwell 0.1 s at a time; inspect flux date code and pad cleanliness
Bridging between adjacent pads Excess solder volume; spot offset; pad spacing too tight for the deposit Reduce ball/paste volume 10%; re-run vision alignment; consider smaller spot
Voiding under thermal pad Flux outgassing on a fast ramp; uneven pad flatness Add a 0.2–0.5 s preheat hold, slow the ramp, check coplanarity by X-ray after sectioning
Solder spatter / micro-balls Moisture in paste or flux; ramp too aggressive Dry-store paste, reduce ramp rate, verify dispense needle condition
Board discoloration or laminate damage Peak overshoot; high power density in a small spot; no backside support Re-calibrate emissivity, verify pyrometer spot size, add backside support or heat sink
Joint-to-joint inconsistency Power drift; contaminated optics window Log power at start and end of shift; add window cleaning to the PM schedule

What Acceptance Checks Prove the Process Is in Control?

Build the qualification package around measurable outputs, not visual impressions alone:

  • Temperature repeatability: record peak and time-above-liquidus for at least 30 consecutive joints; a spread within ±5 °C at peak indicates a stable loop.
  • Fillet and wetting: wetting angle below 90°, continuous fillet on lead and pad, no icicling or lift-off, judged against the class requirements you build to.
  • Voiding: X-ray the thermal pads; single-digit percentage void area is a workable target for most power and connector joints, with tighter limits on die-attach-type interfaces.
  • Mechanical strength: ball shear or wire pull on sampled joints, with the mean and standard deviation tracked over time rather than a single pass/fail reading.
  • Cross-section: intermetallic layer 1–4 µm, no Kirkendall voids, no cracks at the fillet heel.
  • Process capability: run a Cpk on peak temperature and on solder volume; values above 1.33 show the window is controlled, not just centred.

On ULiLASER equipment these checks map directly onto the machine’s logged data — profile records, vision alignment offsets and AOI results — which is what makes an audit trail straightforward during customer qualification.

FAQ

What is the difference between laser soldering and laser welding?
In soldering, a filler alloy melts below roughly 450 °C and wets the base metal, which stays solid. In welding, the base metal itself melts and fuses. The two use different power densities, optics and quality standards, and soldering equipment is not a substitute for a welding system.

How long does one laser-soldered joint take?
Small SMT and connector joints typically complete in 0.3–1.5 s of heating, plus 0.1–0.5 s of cooling and the vision and feeding time. A single-head cell commonly produces 20–60 joints per minute depending on travel distance and solder delivery method.

Can laser soldering handle thermal pads and ground planes that sink heat away?
Yes, but the window narrows. Large copper areas need a wider spot or a short preheat stage, and the pyrometer must be positioned so it reads the joint rather than the surrounding plane. Closed-loop control compensates for much of the heat sinking automatically, provided emissivity is calibrated on that specific surface.

Is nitrogen mandatory?
Not always, but it widens the process window noticeably on fine-pitch and lead-free work by suppressing oxidation during the fast ramp. If you skip it, expect a narrower energy window and more sensitivity to pad finish and storage conditions.

Do I still need AOI if the temperature profile is closed-loop controlled?
Yes. Temperature control confirms the thermal history, not the solder volume, placement or fillet geometry. AOI and periodic X-ray remain the checks that catch feeding faults and voiding.

If you are scoping a laser soldering process for a specific board, connector or package, send us your pad geometry, alloy and thermal budget and our process engineers can help you define a starting parameter window on ULiLASER equipment.